Different system for cars, light commercial vehicles (LCV), heavy duty vehicles and non-road mobile machinery (NRMM) are available. On-board measurements for in-service conformity can also be performed. Measurement procedure at FVT certified according to ISO 17025.


 

AVL M.O.V.E PEMS

System: AVL MOVE incl. PN PEMS
Measured species: CO2, CO, NO2, NO, THC (for HDV) as well as particle number
Exhaust gas mass flow: Exhaust Gas Mass Flow Meter (EFM)
Data recording: Data logger for recording emission data and other cycle-relevant information such as speeds, temperatures, air pressure, humidity, GPS Position and ECU data

 

IAG OFS mobile FTIR

System: IAG OFS
Gemessene Abgaskomponenten: Acetylene, Acetaldehyde, 1,3 Butadiene, Butane, COS, CH4, CO2, CO, Ethane, Ethylene, Formaldehyde, Formic Acid, H2O, Methanol, N2O, NH3, NMHC, NOx (NO/NO2), Propane, Propylene, SO2, THC
Abgasmassenstrom: Exhaust Gas Mass Flow Meter (EFM)
Datenaufzeichnung: Data logger for recording emission data and other cycle-relevant information such as speeds, temperatures, air pressure, humidity, GPS Position and ECU data

 

DTT PN Measurement System

System: DownToTen PN Measurement System
Gemessene Abgaskomponenten: PN10, PN23 if required, dilution and sampling system with/without heated catalytic stripper for solid or total particel number measurment
Abgasmassenstrom: Exhaust Gas Mass Flow Meter (EFM)
Datenaufzeichnung: Data logger for recording emission data and other cycle-relevant information such as speeds, temperatures, air pressure, humidity, GPS Position and ECU data

 

Download testbed description and pricing as PDF

The test systems are operated in cooperation between the Graz University of Technology and FVT mbH.